LightLEEDer Lighting Controller Panel

The LightLEEDer controller is the key to a powerful, dependable, flexible and energy efficient lighting system. LightLEEDer panels come with our new Reliant40 relays which feature a superior four contact design -- the first true 40Amp lighting relay. Reliant40 relays come in 1-, 2- and 3-pole configurations in a robust breaker-style body. LightLEEDer panels range in size from 4 to 64 relay capacity and are equipped with CAT-5 RJ45 connectors for LightSync data line devices and interconnecting panels. Panels include a keyboard and LCD screen, along with USB and TCP/IP connections for easy programming with our free LightLEEDer Pro Software. Add-on modules are available for connecting to BAS, theatrical, or security systems.

  • 365-day programmable Lighting Control Panel
  • Automatic receptacle plug load control
  • All products Made in the USA
  • LightSync™ switch and accessory ready
  • USB, modem and TCP/IP connectivity available
  • Integrated surge suppression
  • Built-in programming backup and restore
  • Connect up to 254 panels and 16,510 devices together
  • Allows network connections across the Internet
  • Suitable for plenum mounting
Accessories

1, 2, 3 Pole Reliant40 Relay Cut Sheet

LightLEEDer R-40 Relay Installation Details

LightLEEDer-EVO Distributed Lighting Controller Cut Sheet

LightLEEDer-EVO Details

LightLEEDer-EVO Wiring Details

LightLEEDer-EVO Installation Details

LightSync G2 Data Line Switch Cut Sheet

LightSync G2 Switch Installation

LightLEEDer Network Controller Module Cut Sheet

LightLEEDer Advance Network Controller Installation Details

LightLEEDer Serial Interface Control Module Cut Sheet

LightLEEDer RS232/RS485 Serial Communications Module Details

LightLEEDer Serial Add-on Module Installation Details

LightSync Occupancy Sensor 8 Input Module Cut Sheet

LightSync Conditional Occupancy Sensor 8 Input Module Details

LightSync Occupancy Sensor 8 Input Module Wiring Details

LightSync Occupancy Sensor Input Module Cut Sheet

LightSync Occupancy Sensor Input Module Details

LightSync Occupancy Sensor Input Module Wiring Details

Leviton Occupancy Sensor Cut Sheets (all)

LightSync Photo Sensor Cut Sheet

LightSync Photocell and Controller Details

LightSync Photo Sensor Controller Wiring Details

LightSync Photo Sensor Controller Installation

LightSync Photo Sensor 4

LightSync Photo Sensor 4 Details

LightSync Photo Sensor 4 Controller Wiring Details

LightSync Photo Sensor 4 Installation Details

LightSync Photo Sensor Photocell Head Cut Sheet

LightSync PSR & PS Cut Sheet

LightSync Power Supply Repeater (PSR) Details

LightSync Power Supply Repeater (PSR) Installation

LightSync 0-10V Isolated Dimming Output Module Cut Sheet

LightSync 0-10V Dimming Module Details

LightSync 0-10V Dimming Module Wiring Details

LightSync 0-10V Dimming Module Installation

LightSync Line Voltage Dimmer Cut Sheet

LightSync Line Voltage Dimmer Details

LightLEEDer DMX 512 Control Module Cut Sheet

LightSync DMX Driver Installation and Configuration Document

Linear Dimming Control Module 0-10V

LightSync Motor Control Module Cut Sheet

LVS EPC-2 Emergancy Power Control

ILC Mobile LightSync Link App Cut Sheet

Mobile LightSync Link App Programming Guide

LightSync Touch Screen Station Programming Package Cut Sheet

LightSync Touch Screen Switch Station Cut Sheet

LightSync Touch Screen Installation

Remote EM Test Switch Wiring Details

LightLEEDer Emergency UL 924 Phase Monitor Module

LightLEEDer Emergency UL 924 Relay Bypass Output Module Cut Sheet

LightLEEDer Expansion Processor Cut Sheet

LightSync Input Module Cut Sheet

LightSync Input Module Details

LightSync Input Module Wiring Details

LightSync Input Module Installation Details

LightSync Classic Data Line Switch Cut Sheet

LightSync G2 Switch Installation

LightSync G2 Switch Faceplate Installation

LightSync Switch Engraving Details

LightSync Touch Switch Cut Sheet

LightSync Disable Key Switch Cut Sheet

LightSync Disable Key Switch Installation

LightSync Disable Key Switch Details

LightSync Serial Input Interface Control Module RS232-485 Details

LightSync Serial Input Module Cut Sheet

LightSync Serial Input Interface Control Module Details

LightSync Serial Input Interface Control Module Enclosure Details

LightSync DMX Driver Module Cut Sheet

LightSync Key Switch Cut Sheet

LightSync Slide Switch Cut Sheet

LightSync Slide Switch Details

LightSync Wireless EnOcean Input Module Cut Sheet

ILC Hardwired Photo Sensor Cut Sheet

Hardwire Photocell Controller Details

Hardwire Photo Sensor to LightSync Input Module Wiring Details

Hardwire Photocell Controller Installation

LightLEEDer Addressable Relay Driver Module

LightLEEDer Dry Contact Output Board Cut Sheet

LightLEEDer Modem Cut Sheet

LightLEEDer Relay Driver Module Cut Sheet

LightLEEDer Relay Simulator Cut Sheet

LightLEEDer Serial Ethernet Control Module Cut Sheet

LightLEEDer Voice Prompted DTMF Telephone Modules Cut Sheet

LightSync Conditional Input Module Cut Sheet

LightSync Conditional Input Module Details

LightSync Conditional Input Module Wiring Details

LightSync Conditional Occupancy Sensor 8 Input Module Cut Sheet

LightSync Data Line Transient Suppressor Cut Sheet

LightSync Data Line Transient Suppressor Installation Details

LightSync Device Hub Cut Sheet

LightSync Hub Details

LightSync Motor Control Module Cut Sheet

LightLEEDer-2 Load Room Controller Cut Sheet

LightLEEDer 4RC Wiring Details

LightLEEDer-2 Room Controller Details

LightLEEDer-4 Load Room Controller Cut Sheet

Features
  • Made in the USA relays and hardware
  • Automatic receptacle plug load and lighting circuit control
  • Programming Options are done with a Integrated keypad with 4-line LCD display or using LightLEEDer Pro software via USB or TCP/IP.
  • LightSync Data Line Device Ready utilizing RJ45 connectors and standard CAT-5 cabling for data line.
  • Network Capability allows you to connect up to 254 panels and 64 LightSync devices per panel, plus an additional 254 devices on the panel network.
  • Internet Capability to interconnect panels across the internet.
  • Relay Groups can comprise any relay on the network and be assigned to any of the 256 available groups controlled by any timer, switch, or other external commands.
  • Relay Presets can be programmed fromany relay ON/OFF patterns and be assigned to any of the 256 available presets -- controlled by any timer, switch, or other external commands.
  • Timer Scheduling for 128 available timers that can turn relays ON or OFF for Time-of-Day, Astronomical times, and Open/Close.
  • Clock Functions include Automatic Astronomical calculation of Sunrise and Sunset, Adjustable Daylight Saving Time and Enable/Disable.
  • Switching Inputs (optional) accepts virtually any type of switch, momentary or maintained, 2- or 3-wire switch and directly powers motion sensors, data line switches and devices.
  • Switch Input Flexibility is provided with time-of-day function change and also has ¨and/or¨ logic built in.
  • Add-On Modules available for each controller, and include BACnet IP, BACnetMSTP,Modbus RTU,Modbus ASCII, N2, LonWorks, DMX512, DTMF telephone switching andmodem.
Physical

Specifications

Relays:

  • Superior breaker style design
  • Switch type override control
  • Lockout feature disables control from panel
  • 40 Amps @ 120, 277 and 347 VAC
  • 1-, 2-, or 3-pole configurations

Safeguards:

  • Power surge and spike suppression up to 123 volts on the 24VAC power input
  • Memory retention for firmware and programming up to 200 years and electrostatic discharge to 4Kv
  • Real-Time-Clock time retention 45 days or greater without power
  • Internal memory backup and restore

Physical:

  • Double-sided construction for mounting directly to breaker box or stand alone
  • Pre-drilled mounting holes for easy installation
  • Provided with a removable hinged locking door for flush or surface mounting, dead front door for 4 size enclosure
  • High voltage barriers separate Normal/Emergency and Class 1/Class 2 wiring

Electrical:

  • 120 or 277 VAC @ 1 Amp, 347 VAC optional

Capacities:

  • Up to 64 single pole relays
  • 2 to 4 add-on modules

Operating Environment:

  • Location: Interior space
  • OperatingTemp.: 0° to 50° C
  • Humidity: 10%- 90%Non-condensing
  • Atmosphere: Non-explosive/corrosive
  • Vibration: Stationary

Certifications and Approvals:

  • UL and CUL listed
  • FCC Part 15
  • Suitable for Plenum Mounting
  • FCC Part 68
  • Title 24
  • ASHRAE compliant