LightMaster LM4 Distributed Lighting Control

ILC's smallest LightMaster Lighting Controller, the LM-4, is a compact and powerful lighting control panel designed for distributed mount applications. This panel will easily integrate into the LightMaster Standard or Expanded Network application. Every LM-4 Lighting Controller is equipped with standard CAT-5 RJ-45 connectors to integrate easily with ILC's data line. The LM-4 also features an additional CAT-5, RJ-45 connector for local switches, photocells and other LightSync devices.
  • 1-4 Relay Outputs
  • 365-day programmable Lighting Control Panel
  • Daylight Savings Time adjustment and Astro Clock standard
  • 48 programmable relay groups, presets, timers
  • RJ45 connectors for CAT-5 data line cable
  • ILC LightSyncTM switch and accessory ready
  • True relay status with Pilot Light and ON/OFF push buttons
  • Equipped for Standalone or ILC Network use
  • Processor Power LED and ON-OFF Switch
  • Optional Add-on Modules available

 

Features

Optional Programming Devices

  • Handheld keypad with LCD display
  • LightMaster Pro Windows software

ILC LightSync Device Ready

  • Utilizes standard CAT-5 RJ-45 plug in interface
  • See ILC Catalog LightSync section for other data line devices

LightSync Network Capable

  • LightSync Standard Network supports up to 32 LightMaster panels
  • LightSync Extended Network supports up to 128 LightMaster panels

Relay Groups

  • Relays may be assigned to any of 48 available groups or presets
  • Relay groups may be assigned to multiple Timers, Switch Inputs, and other panel functions simplifying programming

Open/Close Times

  • Lighting Control Schedules may adjust based on business (retail) Open/Close hours for easy adjustment when operating hours fluctuate
  • Seven standard Open/Close times and 365 custom daily Open/Close times available
  • Scheduled event may be programmed to occur before, after or at Open/Close times

Relay Functions

  • Each relay may be programmed for ON only, OFF only or ON/OFF control
  • Pulsed output for control of external devices such as lighting contactors or other systems
  • HID multilevel control (specialized output control for multilevel HID ballasts including warm-up sequence)

Switch Types

  • The LightMaster may be programmed to accept virtually any type of switch input, momentary or maintained

Switch Input to Relay Output Mapping

  • LightSync switch to relay settings are completely soft, requiring no field rewiring when changes are required
  • Any LightSync switch control any combination of relays, groups or presets

Automatic Power-Up Settings

  • Relays may be programmed to automatically return to ON, OFF or remaining in the state they were in prior to the outage

After Hours Sweeps

  • Individual relay or groups of relays may be programmed to be swept OFF during non-operational hours
  • After hours OFF Sweeps can be set to occur based on time window

Daylight Saving Time Adjustment

  • Automatic adjustment for daylight saving changes (may be enabled or disabled from keypad or software)

Astronomical Clock

  • Automatic calculation of Sunrise and Sunset based on date and geographic position
  • Scheduled events may be programmed to occur before, after or on an astro event

Blink Alert

  • Prior to a scheduled OFF event, lighting loads programmed for a Blink Alert will be momentarily turned OFF then back ON to alert occupants. To avoid the pending OFF sweep, the user simply turns their local switch OFF and then back ON again during the adjustable period (default is 5 min.) prior to the OFF sweep.

Add-On Modules

  • Easy to install add-on modules for applications requiring DMX512, Modbus, N2, BACnet or LonWorks serial communications.

 


 

Specifications

Physical

  • LightMaster lighting controllers are provided with pre-drilled mounting holes for easy mounting to unistrut framing or directly to wall
  • 12" x 10" x 4" NEMA-1 enclosure

Electrical

  • 120 or 277 VAC power supply ready
  • Relays available for several voltages

Operating Environment

  • Location Interior Space
  • Operating 0° to 50° C (32° to 112° F) Temperature
  • Relative 10% to 95% Humidity Non-condensing

Certifications

  • UL, CUL
  • FCC approval for commercial use
  • California Title 24

Capacity

  • 1 to 4 relays

Configuration

  • 10-year minimum NVRAM memory retention in absence of power
  • Minimum 30 day clock retention

 

Related Downloadable Documents

The following are the most commonly related PDF documents used with this product. Select Resource Library at the top of this page for a comprehensive listing of all PDF documents and all categories or contact ILC directly for personal assistance.


LightMaster Relay Timer Types

LightMaster Switch Input Types

LightMaster LM-4 Distributed Lighting Control

LightMaster LM-4 Dimmer Output Module Dimming Control


CAT 5 data cable details


CAT 5 RJ45 connector installation

CAT 5 Cable installation guideline


Latitude longitude for major cities

Network cable run distance detail

NEC Bulletin

LightSync Cumulative Power Worksheet

LightMaster V.6 Firmware Menu Tree


 

Related Tools

The following are the most commonly related Tools used with this product.


LightSync Data Line Distance Calculator