OAC-P OAC-P

Ceiling Mount Occupancy Sensor, PIR, Line Voltage

Model: OAC-P-0500-MV, OAC-P-1500-MV, OAC-P-1500-DMV

The MicroSet Passive Infrared Line Voltage Occupancy Sensing Ceiling Sensor is a motion sensing lighting control that is used for energy savings and convenience.  The sensor is available in both single and dual load control.

The sensor is designed to detect motion from a heat-emitting source (such as a person entering a room) within its field-of-view and automatically switch lights ON. These sensors have multi-segmented lenses. For units to sense motion, the person must cross between two segments. The distance between segments increases the farther you are from the sensor, so motion has to be larger the farther you are from the unit. PIR sensors are considered line-of-sight sensors, meaning that the sensor must be able to have a direct line-of-sight to the person making the motion. The sensor includes self-adaptive technology that continuously self-adjusts sensitivity and time delay in real-time, maximizing the potential energy savings that are available in the particular application. The MicroSet Passive Infrared Line Voltage Ceiling Sensor has an ambient light level sensor. When enabled, the daylighting feature prevents lights from turning ON when the room is adequately illuminated by natural light.

Cutsheets

Ceiling Mount Occupancy Sensor, PIR, Line Voltage

Specifications

Technology:

  • Passive Infrared (PIR) 

Mechanical:

  • Size: 1.42” H x 4.5” W (36.068mm x 114.3mm)
  • Mounting: Mounts directly to ceiling tile, to a 4” square box and round mud ring or to 4” octagon box

Environment: 

  • Operating temperature: 32°F to 104°F (0°C to 40°C)
  • Relative humidity operating: 20% to 90% non-condensing
  • For indoor use only
  • Housing: Durable, injection molded housing. Polycarbonate resin complies with UL 94V-0

Electrical:

  • Power Requirements: 120 to 347 VAC, 50/60 Hz- Neutral Required
  • 120 VAC:
    • Incandescent/Tungsten - 0 to 800W, 50/60 Hz
    • Fluorescent/Ballast - 0 to 1200W, 50/60 Hz
    • Electronic Ballast (LED) 3A
    • Motor Load: ¼ HP @ 125 VAC 
  • :230 VAC
    • Fluorescent/Ballast - 0 to 1200W, 50/60 Hz
    • Electronic Ballast (LED) 3A
  • 277 VAC:
    • Fluorescent/Ballast - 0 to 2700W, 50/60 Hz
    • Electronic Ballast (LED) 3A
  • 347 VAC:
    • Fluorescent/Ballast - 0 to 1500W, 50/60 Hz
    • Electronic Ballast (LED) 3A

Hardware Specifications:

  • LED Indicators:  Red LED for PIR detection 

Controls and Performance:

  • Time delays:  Self-adjustable, 15 seconds/test (10 minutes Auto), or Selectable 5, 15, 30 minutes
  • Coverage:  500 & 1500 sq. ft.
  • Light sensing level:  0 to 300 foot candles

Standards/Ratings:

  • cULus Listed - Energy Management Equipment (UL916)
  • FCC Compliant
  • RoHS Compliant
Features
  • MicroSet self-adjusting time delay and sensitivity
  • Built-in light level sensor
  • Units available for control of single or two separate loads
  • Products tested to NEMA WD 7 - 2011 Occupancy Motion Sensors Standard
  • LED Rated